2.1.2 Repair procedures

To remove the 4-way valve coil
To remove the 4-way valve body
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
Prerequisite: If needed, remove any parts to create more space for the removal of
the 4‑way valve coil.
1 Remove the screw and remove the 4‑way valve coil from the 4‑way valve
body.
c
a Screw
b 4‑way valve coil
c 4‑way valve body
2 Cut all tie straps that fix the 4‑way valve coil harness.
3 Disconnect the 4‑way valve coil connector from the appropriate PCB.
4 To install the 4‑way valve coil, see
Prerequisite: Recuperate the refrigerant from the refrigerant circuit, see
"3.2.2 Repair
procedures" [
1 Remove the 4‑way valve coil from the 4‑way valve body, see
4
procedures" [
 41].
2 Cut the 4‑way valve pipes using a pipe cutter.
INFORMATION
The cutting locations of the 4‑way valve pipes can differ due to the pipe cutter
needing sufficient space to go around the pipes. It is up to the technician to define
the best cutting locations. If any refrigerant pipes are cut, these need to be replaced
during installation of the 4‑way valve body.
a
b
"2.1.2 Repair
4
 133].
2
Components
|
4
"2.10 Plate
work" [
 101].
4
procedures" [
 41].
"2.1.2  Repair