FOR REFERENCES ONLY
6. Other parameters
Extended parameters are provided for sophisticated operation, fine adjustment and other special purposes. Modify
parameter settings as required. Refer to section 11 tables of extended parameters.
6.1
Input/output parameters
6.1.1
Low-speed signal
: Low-speed signal output frequency
Function
When the output frequency exceeds the setting of an ON signal will be generated. This signal
can be used as an electromagnetic brake excitation/release signal.
This signal can also be used as an operation signal when is set to 0.0Hz, because an ON
signal is put out if the output frequency exceeds 0.0Hz.
Output from the open collector output terminal OUT. (Default)
Output from relay output FLA-FLB-FLC is possible depending on the parameter settings.
[Parameter setting]
Title
Low-speed signal output frequency
VFNC3C ENGLISH MANUAL
Function
Output frequency
[Hz]
Set frequency
0
Low-speed signal output
Between OUT-NO terminals
Low-speed signal output:
Inverted
F-1
NOT SUBJECTED FOR RESALE
Adjustment range
0.0 (Hz)
Time [s]
6
Default setting
0.0
ON
OFF
ON
OFF