Agitator Motor Replacement - Cornelius Impulse XL Operator's Manual

Post-mix beverage dispenser
Table of Contents

Advertisement

WARNING
Disconnect power to the unit before servicing following all lock out\tag out procedures established
by the user.Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING
Water and CO2 to the system must be turned off and the system depressurized prior to performing
this service.
Failure to comply could result in serious injury,death or damage to the equipment.
5. Remove four nuts from bolts and
remove the motor.
6. Install new motor by reversing this
procedure.
NOTE -- Be sure there is anti-seize
A
M
GITATOR
1. Disconnect power to the unit.
2. Remove the following:
• front merchandiser by removing screws on the top and lifting up
• key switch wires
• hood by removing screws on the top and lifting up and forward.
3. Unplug motor harness.
4. Remove mounting screw.
5. Slide motor out of retainer slots and
lift up.
compound on the pump
drive tang.
R
OTOR
EPLACEMENT
two Bolts in front and two in Back of Motor
Pump Tang
Mounting
Screw
- 35 -