NOTE --
5. If remote carbonator is used, be sure it is on. Bleed each valve into a
bucket until carbonated water comes out.
6. Be sure that all syrup sources are connected and on. Bleed each valve
into a bucket until syrup comes out.
7. Reinstall drip tray and position water bath over"ow hose in drip tray
indent.
8. Check the system for gas leaks by pressurizing the system and then
turning off the cylinder valve.
cylinder gauge to see if the pressure has dropped.
9. Check the system for water and syrup leaks.

Check for Leaks

1. Bleed air from the lines by activating dispensing valves.
2. Remove air from carbonator (if unit has built-in carbonator) by
opening safety relief valve until water escapes.
3. Check the system for gas leaks by pressurizing the system and
then turning off the cylinder valve.
check the cylinder gauge to see if the pressure has dropped.
4. Check the system for water and syrup leaks.

Reinstall Panels

1. Reinstall top and front vented panels as well as the front stainless
steel panel.
© 2010, IMI Cornelius Inc.
The CO
inlet !tting is sealed inside the carbonator with an
2
O-ring. This !tting rotates freely and must be held by a second
wrench while securing the CO
inlet line.
2
W
ait a couple of minutes and check the
W
ait a couple of minutes and