Cornelius IDC 2 Series Installation Manual

Cornelius IDC 2 Series Installation Manual

With cold carbonation
Hide thumbs Also See for IDC 2 Series:

Advertisement

Quick Links

IDC 2XX WITH COLD CARBONATION
Installation Manual
Release Date: August 20, 2009
Publication Number: 621057403INS
Revision Date: March 11, 2019
Revision: K
Visit the Cornelius web site at www.cornelius.com for all your Literature needs.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDC 2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Cornelius IDC 2 Series

  • Page 1 IDC 2XX WITH COLD CARBONATION Installation Manual Release Date: August 20, 2009 Publication Number: 621057403INS Revision Date: March 11, 2019 Revision: K Visit the Cornelius web site at www.cornelius.com for all your Literature needs.
  • Page 2 Commercial Warranty. Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting from any of the following occurrences, including but not limited to, (1) other than normal and proper use and normal...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Instructions ........... . .1 Read and Follow ALL Safety Instructions .
  • Page 4: Safety Instructions

    Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE. © 2005-2019, Cornelius Inc. - 1 - Publication Number: 621057403INS...
  • Page 5: Safety Precautions

    NOTE: Many units incorporate the use of additional equipment such as ice makers. When any addition equipment is used you must check with the equipment manufacturer to determine the addi- tional weight the counter will need to support to ensure a safe installation. Publication Number: 621057403INS - 2 - © 2005-2019, Cornelius Inc.
  • Page 6: Introduction

    36-3/4 inch (to top of lid) 39-3/4 inch (to top of lid) Operating Pressure 75-psig (max) 75-psig (max) Ambient Operational Temperature 65 to 95 F. (18.3 to 35 65 to 95 F. (18.3 to 35 © 2005-2019, Cornelius Inc. - 3 - Publication Number: 621057403INS...
  • Page 7: Installation

    “traps” or improper drainage will result. NOTE: Cornelius Inc. recommends that a water shutoff valve and water filter be installed in the plain water inlet supply line. A Cornelius Water Filter (P/N 313860000) and QUICK DISCONNECT SET (P/N 313867000) are recommended.
  • Page 8: Adjust Carbonator Co 2 Regulator And Turn Water Inlet Supply Line On

    5. If the carbonator pump appears to be short-cycling where the refill time is 1 - 2 seconds, refer to the Trou- bleshooting section. NOTE: The dispenser is not designed for a wash down environment and must not be placed in an area where a water jet could be used. © 2005-2019, Cornelius Inc. - 5 - Publication Number: 621057403INS...
  • Page 9: Gate Restrictor Plate And Adjustment

    MAX TORQUE 50 in.-lb. Figure 1. Gate Restrictor Plate NOTE: Tighten (4) nuts for fastening lower ice chute in place to 50 in-lbs (max). Draw all four nuts tight uniformly. Publication Number: 621057403INS - 6 - © 2005-2019, Cornelius Inc.
  • Page 10: Idc 2Xx Mounting Template

    ANYWHERE WITHIN S HADED AREA. Figure 2. IDC 2XX Mounting Template NOTE: Recommended counter opening size 9 X 12 for utilities and beverage tubing. Opening can be located anywhere within shaded area. © 2005-2019, Cornelius Inc. - 7 - Publication Number: 621057403INS...
  • Page 11: Drip Tray Drain Assembly

    IDC 2XX with Cold Carbonation Installation Manual RAIN SSEMBLY HOSE CLAMP DRAIN LINE 1" I.D. PLASTIC TUBING (6') WITH INSULATION Figure 3. Publication Number: 621057403INS - 8 - © 2005-2019, Cornelius Inc.
  • Page 12: Flow Diagram - Eight Valve Unit With Twelve Line Cold Plate

    IDC 2XX with Cold Carbonation Installation Manual IAGRAM IGHT ALVE WELVE OLD PLATE Figure 4. © 2005-2019, Cornelius Inc. - 9 - Publication Number: 621057403INS...
  • Page 13: Flow Diagram - Eight Valve Unit With Eight Line Cold Plate

    ALVE IGHT LATE PRIMARY REGULATOR SECONDARY REGULATOR PUMP & MOTOR ASY PRESSURE REGULATOR SYRUP BIB'S CITY WATER OR BOOSTER 60 PSIG PUMP MAY BE REQUIRED WATER FILTER CYLINDE Figure 4A. Publication Number: 621057403INS - 10 - © 2005-2019, Cornelius Inc.
  • Page 14: Flow Diagram - Eight Valve Unit With Two Prism Valves

    IDC 2XX with Cold Carbonation Installation Manual IAGRAM IGHT ALVE RISM ALVES Figure 5 © 2005-2019, Cornelius Inc. - 11 - Publication Number: 621057403INS...
  • Page 15: Flow Diagram - Ten Valve Unit With Twelve Line Cold Plate

    IDC 2XX with Cold Carbonation Installation Manual IAGRAM ALVE WELVE LATE Figure 6 Publication Number: 621057403INS - 12 - © 2005-2019, Cornelius Inc.
  • Page 16: Flow Diagram - Ten Valve Unit Ten Line Cold Plate

    REGULATOR 60 PSIG PRIMARY PUMP & MOTOR ASY REGULATOR 110 PSIG WATER FILTER PRESSURE REGULATOR CITY CYLINDER OR BOOSTER WATER PUMP MAY BE SYRUP BIB's 60 PSIG REQUIRED Figure 7 © 2005-2019, Cornelius Inc. - 13 - Publication Number: 621057403INS...
  • Page 17: Flow Diagram - Ten Valve Unit Two Prism Valve

    IDC 2XX with Cold Carbonation Installation Manual IAGRAM ALVE RISM ALVE Figure 8 Publication Number: 621057403INS - 14 - © 2005-2019, Cornelius Inc.
  • Page 18: Wiring Diagram - 120V Unit

    IDC 2XX with Cold Carbonation Installation Manual - 120V U IRING IAGRAM Figure 9. © 2005-2019, Cornelius Inc. - 15 - Publication Number: 621057403INS...
  • Page 19: Wiring Diagram - 230V Unit

    IDC 2XX with Cold Carbonation Installation Manual - 230V U IRING IAGRAM Figure 10. Publication Number: 621057403INS - 16 - © 2005-2019, Cornelius Inc.
  • Page 20: Wiring Schematic

    IDC 2XX with Cold Carbonation Installation Manual IRING CHEMATIC Figure 11. © 2005-2019, Cornelius Inc. - 17 - Publication Number: 621057403INS...
  • Page 21: Troubleshooting

    Poor ice quality due to water quality or ice Correct water quality or repair ice maker maker problems No 24VAC to valves Restore 24 VAC to valves Beverage does not dis- pense No CO pressure Restore CO pressure Publication Number: 621057403INS - 18 - © 2005-2019, Cornelius Inc.
  • Page 22 Check that the umbilical cord is connected from the unit to the pump motor terminal box. © 2005-2019, Cornelius Inc. - 19 - Publication Number: 621057403INS...
  • Page 23 5 minutes. Defective liquid level probes Replace both liquid level probes Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of beverage system. Publication Number: 621057403INS - 20 - © 2005-2019, Cornelius Inc.
  • Page 24: Diagnostics Guide For Main Control Board

    Unplug the unit and plug it back in. Entered when pump has run This is an error This will reset the unit's main ON continuously continuously for 5 minutes condition. control board and restart the carbonator pump. © 2005-2019, Cornelius Inc. - 21 - Publication Number: 621057403INS...
  • Page 25 IDC 2XX with Cold Carbonation Installation Manual Publication Number: 621057403INS - 22 - © 2005-2019, Cornelius Inc.
  • Page 27 Cornelius Inc. www.cornelius.com...