Cornelius Impulse Non-Carbonated Post-Mix Beverage Dispenser Installation And Operation Manual

Cornelius Impulse Non-Carbonated Post-Mix Beverage Dispenser Installation And Operation Manual

Cornelius non-carbonated post-mix beverage dispenser installation & operation manual

Advertisement

®
IMPULSE
Non-Carbonated Post-Mix Beverage Dispenser
Installation & Operation Manual
Release Date: December 16, 2003
Publication Number: 859000159INS
Revision Date: NA
Revision: A
www.cornelius.com

Advertisement

Table of Contents
loading

Summary of Contents for Cornelius Impulse Non-Carbonated Post-Mix Beverage Dispenser

  • Page 1 ® IMPULSE Non-Carbonated Post-Mix Beverage Dispenser Installation & Operation Manual Release Date: December 16, 2003 Publication Number: 859000159INS Revision Date: NA Revision: A www.cornelius.com...
  • Page 2: Contact Information

    Appropriate safety precautions should be followed and all local safety and construction requirements should be met. To inquire about current revisions of this and other documentation, or for assistance with any Cornelius product contact: IMI Cornelius Inc.
  • Page 3: Table Of Contents

    TROUBLESHOOTING ..........12 © 2003, IMI Cornelius Inc.
  • Page 4 Impulse Installation and Operation Manual Publication Number: 859000159INS - ii - © 2003, IMI Cornelius Inc.
  • Page 5: Safety

    Personnel exposed to high concentration of CO gas will experience tremors which are followed rapidly by loss of consciousness and death. SYSTEM DIMENSIONS © 2003, IMI Cornelius Inc. Non-Carbonated Impulse Installation & Operations Manual SAFETY ERSONNEL —...
  • Page 6: Installation

    — To avoid possible serious injury or death the ELCB (earth leakage circuit — To avoid possible electrical shock the unit must be electrically grounded — The wiring must be properly grounded and connected through a 10-amp - 2 - © 2003, IMI Cornelius Inc.
  • Page 7: Installation Procedure

    When the ice on the © 2003, IMI Cornelius Inc. Non-Carbonated Impulse Installation & Operations Manual lines through counter or wall. To comply with NSF International...
  • Page 8: Connect Concentrate And Water Lines

    Adjust the concentrate-to-water ratio of each valve using the concentrate adjuster on the left side of each valve. Hold cup under valve and dispense beverage for a specific time (such as 4 seconds). Publication Number: 859000159INS Concen- trate diver- sion tube Concentrate adjuster on right Ratio cup - 4 - © 2003, IMI Cornelius Inc.
  • Page 9: Adjusting Flow Rates

    0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con- centrate flow rate.) Finished Drink oz./sec. © 2003, IMI Cornelius Inc. Non-Carbonated Impulse Installation & Operations Manual Flow Rates oz./sec. Based on 5:1 Ratio Water oz./sec.
  • Page 10: Operations

    Install a full bag-in-box and connect the concentrate tube. DJUSTMENTS Water-to-Concentrate Ratio Adjustment The ratio adjustment should only be done by a qualified service person. Publication Number: 859000159INS OPERATIONS to power on the unit. to activate valves. - 6 - ON/OFF switch © 2003, IMI Cornelius Inc.
  • Page 11: Cleaning & Checks

    A. Place waste container under applicable dispensing valve. B. Activate the dispensing valve for one minute to purge all detergent solution and flush out the con- centrate system. © 2003, IMI Cornelius Inc. Non-Carbonated Impulse Installation & Operations Manual Diffuser...
  • Page 12 Dispose of waste sanitizing solution in a sanitary sewer, not in a storm drain, then thoroughly rinse the inside and the outside of the container that was used for sanitizing solution to remove all sanitiz- ing solution residue. Publication Number: 859000159INS - 8 - F (21 © 2003, IMI Cornelius Inc.
  • Page 13: Reference Material

    Non-Carbonated Impulse Installation & Operations Manual REFERENCE MATERIAL IRING IAGRAM © 2003, IMI Cornelius Inc. - 9 - Publication Number: 859000159INS...
  • Page 14 DISPENSER SYRUP SUPPL Y (SYRUP T ANKS OR BAG-IN-BO X SYSTEM) LINE LEGEND PLAIN W A TER SYRUP CARB W A TER External Carbonator - 10 - NON-CARBONA TED DRINK DISPENSING V AL VE (6) © 2003, IMI Cornelius Inc.
  • Page 15 Non-Carbonated Impulse Installation & Operations Manual © 2003, IMI Cornelius Inc. - 11 - Publication Number: 859000159INS...
  • Page 16: Troubleshooting

    • Plug in Unit power cord or check for blown fuse or tripped circuit breaker. • Connect dispensing valves power cord. • Connect or replace wiring. • Replace inoperative part. • Open water inlet supply line shutoff valve. © 2003, IMI Cornelius Inc.
  • Page 17 DOES NOT OPERATE” paragraph plus the preceding. CONDENSER FAN MOTOR NOT OPERATING. AGITATOR MOTOR NOT OPER- ATING. © 2003, IMI Cornelius Inc. Non-Carbonated Impulse Installation & Operations Manual Troubleshooting Refrigeration System • Ice bank sufficient. • Unit power cord unplugged or control board power switch in “OFF”...
  • Page 18 • Remove obstruction. • Voltage must be at least 103 volts at the compressor termi- nals when compressor is trying to start. • Tighten connections or replace broken wiring. • Replace agitator motor as instructed. © 2003, IMI Cornelius Inc.
  • Page 19 blank...
  • Page 20 IMI Cornelius Inc. One Cornelius Place Anoka, MN 55303-1592 U.S.A.

This manual is also suitable for:

Impulse non-carbonated post-mi

Table of Contents