H. Connect the Inner Knee Brace Channels to the Outer Knee Brace Channels, as shown in Detail Y,
using the 5/16” 18 x 7/8” bolts, flat washers, and flange nuts, in the holes nearest to each end of
the Inner and Outer Channels (see Detail Y).
If the holes do not line up, adjust the Lower Knee Brace Clamp up or down the pole slightly to get
the holes in the Channels to align.
Tighten all of the 5/16” hardware to 144 in lbs (dry)
Note: There must be a minimum 6” overlap of the inner and outer channels