  • Page 1 Installation Manual UNI-PGRM Instruction Manual v5.2 For models: UNI-PGRM/1P1 UNI-PGRM/2P1 UNI-PGRM/3P1 UNI-PGRM/4P1 UNI-PGRM/5P1 UNI-PGRM/5P2 UNI-PGRM/6P1 UNI-PGRM/6P2...
  • Page 2: Installer Responsibility

    Customer Support Tamarack Solar makes every effort to ensure your mounting kit is easy to install. If you need assistance at any point in your installation or have suggestions on how we can improve your experience, call customer support at 1-800-819-7236 or email us at sales@tamaracksolar.com...
  • Page 3 UNI-PGRM-END END CLAMP NO matter what version of the PGRM Kit you are using, there are two End Clamps per kit, one clamp for each end of the mount. End Clamps are designed to grab the flange on the underside of the solar module frame.
  • Page 4 Horizontal Beam Length and Post Placement Calculations Use 3-inch Sch-40 pipe (3.5-inch OD) steel pipe. Compute Horizontal Beam Length with the formula below. W= Module Width (inches) Q= Quantity of Modules Beam Length Formula: Length (inches) = 4.82 + (Q x W) + ((Q – 1) x 1.28) This is the minumum length required.
  • Page 5 Install Module Clamps Position and place the Mid Clamps and End Clamps onto the Main Beam at the marked locations. See the spac- ing info on the previous page. Use a level to put each Mid and End Clamps in a horizontal position before tightening their U-bolts Tighten the U-bolt nuts just enough to hold the horizontal position as you will be placing solar modules onto them in next steps.
  • Page 6: End Clamp Installation

    Tighten Mid Clamp U-Bolts As each module clamp is positioned tight against module frames, thighten the U-Bolt nuts through the square access holes on the top of the top clamps. Torque the U-Bolts nuts to 20 ft-lbs. End Clamp Installation Install an End Clamp at both ends of the mount, tightening the U-bolts just enough to hold them in a horizontal position.
  • Page 7 Set Final Angle All of the modules should be horizontal at this point. Check to make sure that all of the module clamp bolts and U-bolts are tightened to the proper torque specifications before proceeding. Loosen all the U-Bolt nuts on the PGRM Cap(s). Use both hands to rotate the entire array to the desired angle and re-tighten the U-Bolt nuts on the PGRM Cap(s).
  • Page 8: Warranty Information

    The Warranty does not cover any defect that has not been reported in writing to Tamarack Solar within ten (10) days after discovery of such defect. Furthermore, it does not cover units that have been altered, modified or repaired without written authorization from the manufacturer or its authorized representative, or units used in a manner or for a purpose other than that specified by the manufacturer.