2.2.1.2 Multi-groups system parameter (Max. 6 groups per system)

For multi-groups operation, please make sure the battery type in the whole system is
the same, please make sure the battery amount of each group is the same.
Product Type
Battery System Voltage
(Vdc)*
Battery System group
amount(pcs)
Battery System capacity (AH)
Battery System Operation
Current(Amps, Standard)
Battery System Operation
Current(Amps, Normal)
Battery System Operation
Current (Amps, Max.@15s)
P-Combiner 3/6 Operation
Current (Amps, Normal)
P-Combiner 3/6 Operation
Current (Amps, Max.@15s)
*The Battery System Voltage is varying depends on battery amount in serial per group.
**The current is based on BMS theoretical operation current to consider. If use P-
Combiner 3 as the combiner box of the multi-groups` battery system wiring connection,
the max. continuous operation current is 50Amps, max. peak operation current is
80Amps for 15sec. for the battery system. Please make sure the real operation current
not exceed the combiner box power rating.
***The current is based on BMS theoretical operation current to consider. If use P-
Combiner 6 as the combiner box of the multi-groups` battery system wiring connection,
the max. continuous operation current is 100Amps, max. peak operation current is
160Amps for 15sec. for the battery system. Please make sure the real operation current
not exceed the combiner box power rating.
Force-H2-V2 in multi-groups
2
3
74
111
14.8
22.2
37
55.5**
84**
126**
168*** 210***
50
80
9
192 / 288 / 384
4
5
148
185
29.6
37
74
92.5
100
160
6
222
44.4
111***
252***