3. Use the pipe or wall mounting hardware to mount a remote electronics
4. Ensure the conduits drop vertically from the transmitter and the conduit is
Rosemount OCX8800A
Figure 2-2: Adapter Plate Installation
Dimensions are in inches with millimeters in parentheses. Only adapter
plate is furnished by Emerson.
A. Plate size (see
Table
B. Stud size (see
Table
C. Bolt circle diameter (see
D. Cross section
E. Masonry stack wall
F. Field weld pipe to adapter plate
G. Pipe 3 in. schedule 40. Sleeve length optional.
H. Bolt adapter plate to outside wall surface. Joint must be air-tight.
I. Metal stack or duct wall
J. Weld or bolt adapter plate to metal wall. Joint must be air-tight.
K. Metal wall stack or duct construction
L. Masonry wall stack construction
Table 2-4: Adapter Plate Kit-Mounting Dimensions
Type part
Plate size "A"
number
(1)
ANSI (PN
6.00 in. (152 mm)
4512C34G01)
DIN (PN
7.5 in. (191 mm)
4512C36G01)
(1)
Part numbers for adapter plates include attaching hardware.
housing.
Choose a location that does not exceed the length of the electronics cable
ordered.
routed below the level of the conduit ports on the housing to form a drip
loop.
2-4)
2-4)
Table
2-4)
Stud size "B"
⅝-11 UNC-2A
M-16 x 2.0-6g
Install
December 2022
Bolt circle
diameter "C"
4.75 in. (121 mm)
5.71 in. (145 mm)
31