6 Troubleshooting

Danger
Risk of death resulting from improper maintenance /
repair.
There is a risk of injury for persons performing tasks for
which they are neither qualified nor have received
appropriate training.
 The maintenance / repair of the device may be
performed only by persons who are familiar with this
task, have been instructed with regard to the
associated hazards and who possess the necessary
qualifications.
 All technical safety conditions have to be satisfied prior
to performing maintenance / repairs.
Wechs el ein- auf z weis paltig

6.1 Troubleshooting by the operator

Fault
lit red permanently
29
Risk of death by electric shock!
Components have voltage applied.
Contact with current conducting parts results in an electric
shock, burns or death.
When working with the electrical system, the following
points must be observed:
 Disconnect device from voltage.
 Secure device from being turned back on.
 Ensure that no voltage is applied.
 Earth and short-circuit the unit.
 Cover neighbouring componets that are under voltage
Cause
Self-test of the charging station is
faulty.
Thermal shutdown of the charging
station.
Internal system error.
Danger
and secure the danger area.
Notes on troubleshooting
Acknowledge the fault with multi-
function button.
Wait until the charging station has
cooled down.
Displaying the error message with
service interface or Charge APP.
Acknowledge the fault with multi-
function button.
If you cannot rectify the fault, ask a
qualified electrician to check the
charging station.