Time Synchronisation - Mennekes AMTRON Xtra User's Operation Manual

Wallbox
Hide thumbs Also See for AMTRON Xtra:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 36
4.8.2.1
Calling up the service interface
Follow these steps to access the service interface:
1. Enter IP address and port number in the address bar of
your Internet browser (http://AMTRONIP: 25000).
2. Enter PIN 1 (APP PIN, see set-up data sheet) of the
charging station.
3. The main menu of the service interface opens.
Fig. 14: Main menu
4. Select the required submenu.
For some parameters, tooltips with further information
are available. Point your mouse over the "?" on the
appropriate parameter. Clicking is not necessary.

4.8.3 Time synchronisation

During the initial setting-up process and after a power failure
of more than 4 hours, a clock synchronisation is necessary.
Time synchronisation is possible with a smartphone / tablet
over the charge APP or with a PC running the service
interface in an Internet browser.
Time synchronisation with a smartphone / tablet
Time synchronisation with smart phone / tablet over the
charge app takes place automatically as soon as a connection
to the charging station has been established. There is no
need for further action.
23
Time synchronisation with PC
Time synchronisation with a PC takes place with the service
interface in an Internet browser
Carry out the following steps to synchronise time in the
service interface.
1. Open the service interface.
2. Select the submenu "Customer Settings" in the service
interface.
3. The menu "Time Info" shows the settings required for
the setting-up process.
Fig. 15: Menu "Customer Settings / Time Info"
4. The value "Local Timestamp" is required in format
Unixtime.
5. You can convert the current date and time with a
timestamp converter such as www.unixtime.de.
6. Enter the value obtained in the field "Local
Timestamp".
7. Activate the input filed "Currently Summer" during
daylight saving time.
8. Set the input filed "Timezone Offset" to the default
value "60".
The "Timezone Offset" is the difference between the
local time zone and the Coordinated Universal Time
(UTC) in minutes.
Example of Germany and Central Europe
The difference between the local time zone and UTC is
1 hour; therefore, set the parameter "Timezone
Offset" to 60 minutes.
9. Confirm the entry with "Submit".
The charging station is now ready for operation.