Terminating The Charging Process; Power Failure During Charging Process; Managing Rfid Cards; Adding Rfid Cards With The Master - Mennekes AMTRON Xtra User's Operation Manual

Wallbox
Hide thumbs Also See for AMTRON Xtra:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 36
The maximum available charging current depends on the
following points
 Power rating of the charging station.
 Features / version of the charging station.
 Current-carrying capacity of the cable.
 Configuration during setting-up process and setting of
the charging current over the Charge APP.
 Configuration of operating modes "Time-Controlled",
"External Tariff Signal" and "Energy Manager".

4.5.5 Terminating the charging process

Caution
Damage to the charging cable.
Pulling the cable may cause cable breaks and other
damages.
Remove the charging cable only by pulling the plug from
the charging socket.
1. Press the multi-function button on the charging station
(see Chapter 4.3.1 "Terminating an on-going charging
process" on page 11) or terminate the charging process
at the vehicle.
2. Remove the plug of the charging cable from the
charging socket (only for charging stations with
integrated charging socket type 2).
3. Remove the charging cable from the vehicle.

4.5.6 Power failure during charging process

A power failure aborts the charging process.
The charging plug of charging stations with charging socket
type 2 is unlocked and removed.
If the charging plug cannot be pulled out, an actuator has
mechanically interlocked the charging plug.
 See Chapter 6 "Troubleshooting" on page 29.
19

4.6 Managing RFID cards

For RFID authorization, prior once-off registration of the
user's RFID card at the charging station is required.
The charging station can manage up to 100 RFID cards (2x
master, 98x users) in an internal database (whitelist).
4.6.1 Adding RFID cards with the master RFID card
You can add RFID cards to the internal database (whitelist)
with the master RFID card.
Adding a new RFID card:
1. Hold the master RFID card against the RFID symbol to
activate teach mode.
 The symbol
on the LED info bar flashes rapidly.
2. Hold the RFID card for teaching against the RFID symbol
within 30 seconds.
 The symbol
on the LED info bar flashes briefly and
then continues to flash rapidly. Teach mode is extended
by an additional 30 seconds.
3. Hold another RFID card against the RFID symbol for
teaching or hold the master RFID card against the RFID
symbol to terminate teach mode.
 The RFID card has been added to the internal database
(whitelist).
If during teach mode for an RFID card the symbol
lights up permanently, the internal database (whitelist) is
full and no more cards can be added.
4.6.2 Adding and deleting RFID cards with the
Charge APP
You can manage the database (whitelist) comfortably by
using the Charge APP on a smart phone or tablet.
4.6.3 Adding and deleting RFID cards with the

service interface

You can add RFID cards to or remove from the internal
database (whitelist) with the service interface.
 See "Menu "Whitelist Operation"" on page 27.