5 Maintenance

Danger
Risk of death resulting from improper maintenance /
repair.
There is a risk of injury for persons performing tasks for
which they are neither qualified nor have received
appropriate training.
 The maintenance / repair of the device may be
performed only by persons who are familiar with this
task, have been instructed with regard to the
associated hazards and who possess the necessary
qualifications.
 All technical safety conditions have to be satisfied prior
to performing maintenance / repairs.
Danger
Risk of death by electric shock!
Components have voltage applied.
Contact with current conducting parts results in an electric
shock, burns or death.
When working with the electrical system, the following
points must be observed:
 Disconnect device from voltage.
 Secure device from being turned back on.
 Ensure that no voltage is applied.
 Earth and short-circuit the unit.
 Cover neighbouring componets that are under voltage
and secure the danger area.

5.1 Maintenance plan

Carry out the following maintenance work at the specified
intervals.
Maintenance interval every 6 months (biannually)
Part / component
Maintenance work
Enclosure
Visual inspection for defects or
damage.
Check the device for secure
fastening.
Clean the outside of the enclosure
with damp cloth.
Front panel
Visual inspection for defects or
damage.
Switching and safety
Visual inspection for defects or
devices
damage.
Check the function of the circuit
breaker (CB).
See Chapter 4.3.3 on page 11.
Maintenance interval every four years
In addition, carry out all maintenance specified in
Maintenance interval every 6 months (biannually).
Part / component
Maintenance work
Cable connections
Visual inspection for defects or
and connectors
damage.
Charging station
Visual inspection for defects or
damage.
Check function
System check
Ask a qualified electrician to check
the system according to VDE0100.