Functional description for operating mode time-controlled (internal)
Start of charging
process
Controlling the charging
process
Changing the operating
mode
Response to power
failure
13
Without RFID card:
 Automatically after connection to the vehicle
With RFID card:
 Authentication with valid RFID card
 Manually by selecting a valid RFID card in Charge APP
By using the internal timer:
 Adapting the charging current depending on the active period (main tariff / off-peak tariff).
By using the Charge APP
 Terminating the charging process (stop)
By using the multi-function button:
 Terminating the charging process (stop)
The stop function with the multi-function button must be enabled during the setting-up
process.
With RFID card:
 Terminating the charging process (stop, with the same card used for starting the charging
process)
In operating mode "Time-Controlled (internal)" , all functions in operating modes
"External Tariff Signal" and "Energy Manager" are suspended. The charging power, for
example, will not be controlled over the external tariff-switching signal or the "SUNNY
HOME MANAGER".
By using the Charge APP during a charging process:
 Change to operating mode "Manual (Remote)".
The change of operating mode will apply to the on-going charging process. The following
charging process is carried out according to the mode selected in the user settings of the Charge
APP.
In the user settings of the Charge APP:
 Changing to all operating modes configured during the setting-up process.
The change of operating mode will apply for the on-going and subsequent charging processes.
By using the service interface:
 Changing to all operating modes configured during the setting-up process.
The change of operating mode will apply for the on-going and subsequent charging processes.
The response to power failure is configured during the setting-up process.
 The charging process is aborted (default with RFID card reader).
 The charging process is continued (default without RFID card reader).