APRILIA TUONO V4 R 2010 Service Station Manual page 139

Table of Contents

Advertisement

TUONO V4 R
Starter switch P0169
signal not valid.
Error cause
Fault in the switch (lock) of the engine start-up. The instrument panel does not indicate the
presence of this error even in the ATT status.
Troubleshooting
Check the locking cause and restore.
level indicators
See also
Fuel pump
Fuses
Specification
A) 5A fuse
B) 5A fuse
C) 15A fuse
D) 7.5A fuse
E) 15A fuse
F) 15A fuse
G) 15A fuse
Auxiliary fuses are placed in the central part of the motorcycle, under the rider saddle.
CAUTION
THREE OF THE FUSES ARE SPARES (H).
Specification
L) 30A fuse
Main fuses are placed in the rear part of the motorcycle, under the passenger seat.
SECONDARY FUSES DISTRIBUTION
Instrument panel, turn indicators, speed and instrument panel
Coils, injectors, fuel pump, oxygen sensor and secondary air
MAIN FUSES - DISTRIBUTION
Battery recharge and vehicle current consumers, injection cur-
Desc./Quantity
Stop and running lights relay
diagnostics.
Control unit
Control unit
High beam/low beam, horn.
valve
Fans.
Desc./Quantity
rent consumers (red and red/white cables), fan relay.
Electrical system
ELE SYS - 139

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tuono v4 r 2011Tuono v4 r 2012Tuono v4 r 2013

Table of Contents