Installing The Pump Set In A Suction, Pressure Or Cooling Shroud - KSB UPA Installation & Operating Manual

Submersible borehole pump
Hide thumbs Also See for UPA:
Table of Contents

Advertisement

40 of 98
5 Installation at Site
CAUTION
Incorrect position of support frame and pedestal
Bending or deformation of the pump set!
▷ Observe the following positions of the support frame and pedestal:
Support frame for the motor: mounting clamps at the casing flanges
Pedestal for the pump: last stage or lift check valve / connection branch.
1
3
Fig. 15: Mounting the pump set on support frame and pedestal (example)
1
Motor
3
Support frame
ü The safety regulations have been observed. (ð Section 5.1, Page 25)
ü The structural dimensions have been verified.
ü The water reservoirs have been installed.
ü The motor fill has been checked and topped up if required.
ü Extension cables have been connected to the power cable, measuring cable and
control cable.
1. Undo the ties holding the cable guard. Remove the cable guard.
2. Fasten the support frame and pedestals to the pump set. Position and align the
assembly on the foundation.
3. Mark and drill the holes for the fixing bolts on the foundation and fasten the
pump set with the support frame / pedestals on the foundation.
4. Run the power cable through the foot of the pump pedestal. Fasten the power
cable to the pump and to the lift check valve / connection branch with cable
ties.
5. Securely fasten all electric cables to prevent them from fluttering in the water
flow. Use a cable conduit if necessary.
6. Install the piping.
NOTE
Fit an expansion joint between the piping and the pump set to prevent any piping
forces and piping vibrations from affecting the pump set.
7. Fasten all electric cables to the riser with cable ties.
NOTE
Fasten all electric cables to the piping every three metres as well as upstream and
downstream of any pipe bends by means of suitable fasteners, e.g. cable ties.
This prevents any fluttering of the electric cables in the water flow. Use a cable
conduit if necessary.

5.4.3 Installing the pump set in a suction, pressure or cooling shroud

For special operating conditions submersible borehole pumps can be fitted with a
pressure, suction or cooling shroud. See order documentation.
For these applications always observe the separate order documentation.
UPA / UPA S