5 Installation at Site

5.4.1 Mounting the pump set on pedestals

Applicable to pump sets with the following motors: DN 100, UMA 150, UMA-S 150,
UMA 200, UMA-S 200, UMA 250, UMA-S 250
CAUTION
Incorrect position of the pedestals
Bending or deformation of the pump set!
▷ Observe the following positions of the pedestals:
Pedestal for the motor: middle of the motor
Pedestal for the pump: last stage or lift check valve / connection branch.
3
1
Fig. 14: Mounting the pump set on pedestals (example)
1
Motor
3
Motor pedestal
The required foundation bolts (M12 × 200) shall be provided by the operator.
ü The safety regulations have been observed. (ð Section 5.1, Page 25)
ü The structural dimensions have been verified.
ü The motor fill has been checked and topped up if required.
ü Extension cables have been connected to the power cable, measuring cable and
control cable.
1. Undo the ties holding the cable guard. Remove the cable guard.
2. Fasten the pedestals to the pump set. Place the pump set on the foundation
with the pedestals and level it.
3. Mark and drill the holes for the foundation bolts on the foundation. Fasten the
pump set to the foundation via the pedestals.
4. Run the power cable through the foot of the pump pedestal. Fasten the power
cable to the pump and to the lift check valve / connection branch with cable
ties.
5. Securely fasten all electric cables to prevent them from fluttering in the water
flow. Use a cable conduit if necessary.
6. Install the piping.
NOTE
Fit an expansion joint between the piping and the pump set to prevent any piping
forces and piping vibrations from affecting the pump set.
7. Fasten all electric cables to the riser with cable ties.
NOTE
Fasten all electric cables to the piping every three metres as well as upstream and
downstream of any pipe bends by means of suitable fasteners, e.g. cable ties.
This prevents any fluttering of the electric cables in the water flow. Use a cable
conduit if necessary.

5.4.2 Installing the pump set on support frame and pedestal

Applicable to pump sets with the following motors: UMA 300, 14D
UPA / UPA S
2
4
2
Pump
4
Pump pedestal
39 of 98

Advertisement

Table of Contents
loading

This manual is also suitable for:

Upa s