5 Installation at Site
L
N
5
4
3
2
1
1~
Fig. 17: Circuit diagram: single-phase (1~) motors with one power cable for DOL
starting
1
Motor
3
Starting device
5
Line conductor
Connections at the starting device
L
N
BK/SW
PE
a
Fig. 18: Starting device, manufacturer A
L
N
PE
PE
Fig. 19: Starting device, manufacturer B
L
Line conductor
N
Neutral conductor
PE Earth conductor; core marking:
green/yellow
When installing the starting device of manufacturer B (terminal assignment 4, 5, 6)
also observe the manufacturer's product literature.
Three-phase (3~) motors with one power cable for DOL starting or operation on a
frequency inverter (VFD)
The three current-carrying conductors are designated U, V and W; the earth
conductor is marked PE.
UPA / UPA S
2
Motor power cable
4
Control unit
BU/BL
BN/BR
c
b
4
5
6
c
b
a
a
Core marking: black
b
Core marking: brown
c
Core marking: grey (blue)