4 Description of the Pump (Set)

4 Description of the Pump (Set)

4.1 General description

Pump for handling clean or slightly contaminated water.
1. Verify the fluid handled and its contents against the data sheet.

4.2 Product information

4.2.1 Product information as per Regulation No. 1907/2006 (REACH)
For information as per chemicals Regulation (EC) No. 1907/2006 (REACH), see
www.ksb.com/ksb-en/About-KSB/Corporate-responsibility/reach/
4.2.2 Product information as per Regulation No. 547/2012 (for 4" and 6" water
pumps) implementing "Ecodesign" Directive 2009/125/EC
▪ Minimum efficiency index: see name plate, key to name plate
(ð Section 4.5, Page 21)
▪ The benchmark for the most efficient water pumps is MEI ≥ 0.70.
▪ Year of construction: see name plate, key to name plate
(ð Section 4.5, Page 21)
▪ Manufacturer's name or trade mark, commercial registration number and place
of manufacture: see data sheet or order documentation
▪ Product's type and size identificator: see name plate, key to name plate
(ð Section 4.5, Page 21)
▪ Hydraulic pump efficiency (%) with trimmed impeller: see data sheet
▪ Pump performance curves, including efficiency characteristics: see documented
characteristic curve
▪ The efficiency of a pump with a trimmed impeller is usually lower than that of a
pump with the full impeller diameter. Trimming of the impeller will adapt the
pump to a fixed duty point, leading to reduced energy consumption. The
minimum efficiency index (MEI) is based on the full impeller diameter.
▪ Operation of this water pump with variable duty points may be more efficient
and economic when controlled, for example, by the use of a variable speed drive
that matches the pump duty to the system.
▪ Information on dismantling, recycling and disposal after decommissioning:
(ð Section 3.6, Page 17)
▪ Information on benchmark efficiency or benchmark efficiency graph for
MEI = 0.70 (0.40) for the pump based on the model shown in the Figure are
available at:
http://www.europump.org/efficiencycharts