Pulling The Pump/Motor/Pump Set Upright - KSB UPA Installation & Operating Manual

Submersible borehole pump
Hide thumbs Also See for UPA:
Table of Contents

Advertisement

3
Observe the cable manufacturer's documentation, DIN VDE 0298-3 and/or the general arrangement drawing.
14 of 98
3 Transport/Storage/Disposal
4. Position the lifting tackle to ensure balanced lifting. The centre of gravity of the
pump set is in the motor area. Watch any add-on parts, such as piping and
electric cables.
5. Lift the pump set out with one or two pieces of lifting equipment, depending
on the pump set size. Place the pump set down on a suitable surface.
6. Use appropriate means to secure the pump set against rolling off.

3.3 Pulling the pump/motor/pump set upright

WARNING
Incorrect positioning/placing down
Personal injury and damage to property!
▷ Position the pump set vertically with the motor below.
▷ Use appropriate means to secure the pump set against tilting and tipping over.
▷ Refer to the weights given in the data sheet.
WARNING
Improper handling when placing the pump set in a vertical/horizontal position
Personal injury and damage to property!
▷ Use one or two pieces of lifting equipment, depending on the pump (set) size.
▷ Use appropriate means to secure the pump set against tilting, tipping over or
rolling off.
▷ Maintain a safe distance during lifting operations (load may swing when being
lifted).
▷ Use additional supports for the transport holder to secure it against tilting.
WARNING
Incorrect handling of the power cable
Personal injury and damage to property!
▷ Secure the power cable against falling down.
CAUTION
Improper storage
Damage to the electric cables!
▷ Observe the minimum bending radius
▷ Only remove the protective caps from the electric cables at the time of
installation.
UPA / UPA S
3)
of the electric cables.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Upa s

Table of Contents