9.2.2 UMA 200, UMA-S 200 mating dimensions

CAUTION
Incorrect pump connection
Damage to the pump set!
▷ The pump shaft must rest on the motor shaft.
Observe the following dimensions:
1.
Axial tolerance: 1.2 ± 0.6 mm
2.
Dimension to be set: 101.5 ± 0.1 mm
67
Fig. 52: UMA 200, UMA-S 200 mating dimensions in [mm]

9.2.3 UMA 250, UMA-S 250 mating dimensions

CAUTION
Incorrect pump connection
Damage to the pump set!
▷ The pump shaft must rest on the motor shaft.
Observe the following dimensions:
+0.7
1.
Axial tolerance: 1.0
2.
Dimension to be set: 101.5 ± 0.1 mm
81
Fig. 53: UMA 250, UMA-S 250 mating dimensions in [mm]
UPA / UPA S
/
mm
-0.6
101,5
±0,1
4,5
Ø7,5
+0,1
67
-0,1
20
101,5
±0,1
5