Mitsubishi Electric NZ2GF2S-60MD4 User Manual page 24

Cc-link ie field network multiple input (voltage/current/temperature) module
Table of Contents

Advertisement

Parameter area (address: 0000H to 01FFH)
For the parameter area, parameters can be set by means of the CC IE Field configuration of the engineering tool, or the
REMTO instruction.
The parameters in the parameter area are backed up to the non-volatile memory.
Parameters backed up to the non-volatile memory are read in the parameter area when the module power supply is turned off
and on or the module returns from remote reset.
For the parameters written from the parameter settings of the CC IE Field configuration of the engineering tool, the write to the
non-volatile memory is also completed at the same time.
When the parameter is written using the REMTO instruction, it is written to the non-volatile memory when Initial data setting
request flag (RY9) is turned on.
At this time, the parameter is written to the non-volatile memory even though it is incorrect.
When the power supply is turned off and on with an incorrect parameter written, the incorrect parameter is read from the non-
volatile memory and an error code is stored to Latest error code (RWr0). Take corrective action according to the error code
list. ( Page 95 List of Error Codes)
■Station-based parameter data
Address
Decimal
Hexadecimal
0 to 255
0000H to
00FFH
■Module-based parameter data
R: Readable through a program, W: Writable through a program
Address
Decimal
Hexadecimal
256
0100H
257
0101H
258
0102H
259
0103H
260
0104H
261
0105H
262
0106H
263
0107H
264
0108H
265
0109H
266
010AH
267
010BH
268
010CH
269
010DH
270
010EH
271
010FH
272
0110H
273
0111H
274
0112H
275
0113H
276
0114H
277
0115H
278
0116H
279
0117H
280
0118H
281 to 511
0119H to 01FFH
*1 This value is the value of factory default or the value of initialization by Parameter area initialization command (address: 1002H).
2 SPECIFICATIONS
22
2.6 List of Remote Buffer Memory Areas
Description
System area
Description
CH1 Input type/range setting
CH2 Input type/range setting
CH3 Input type/range setting
CH4 Input type/range setting
Averaging process setting
CH1 Time Average/Count Average/Moving Average
CH2 Time Average/Count Average/Moving Average
CH3 Time Average/Count Average/Moving Average
CH4 Time Average/Count Average/Moving Average
Input signal error/disconnection detection automatic clear enable/disable
setting
Input signal error detection setting
CH1 Input signal error detection setting value
CH2 Input signal error detection setting value
CH3 Input signal error detection setting value
CH4 Input signal error detection setting value
Conversion setting for disconnection detection
CH1 Conversion setting value for disconnection detection (L)
CH1 Conversion setting value for disconnection detection (H)
CH2 Conversion setting value for disconnection detection (L)
CH2 Conversion setting value for disconnection detection (H)
CH3 Conversion setting value for disconnection detection (L)
CH3 Conversion setting value for disconnection detection (H)
CH4 Conversion setting value for disconnection detection (L)
CH4 Conversion setting value for disconnection detection (H)
Cold junction temperature compensation setting
System area
*1
Default value
Read/Write
0000H
R/W
0000H
R/W
0000H
R/W
0000H
R/W
0000H
R/W
0
R/W
0
R/W
0
R/W
0
R/W
1
R/W
0000H
R/W
50
R/W
50
R/W
50
R/W
50
R/W
1111H
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W

Advertisement