Error history
■Address
Name
CH Error history
■Description
Error history  (address: 0A00H to 0AEFH) records up to 15 errors generated in the module.
Error history 2 (address: 0A10H to 0A1FH) to Error history 15 (address: 0AE0H to 0AEFH) store data in the
same format as that of Error history 1 (address: 0A00H to 0A0FH).
For the error code, refer to the following.
Page 21 List of Remote Buffer Memory Areas
The following table shows the contents stored in Error history 1 (address: 0A00H to 0A0FH).
■Error history 1 (address: 0A00H to 0A0FH)
Address
b15
b14
0A00H
Error code
0A01H
Order of generation
0A02H
First two digits of the year
0A03H
Month
0A04H
Hour
0A05H
Second
0A06H
CH1 Digital output value
0A07H
CH2 Digital output value
0A08H
CH3 Digital output value
0A09H
CH4 Digital output value
0A0AH
System area
0A0FH
Ex.
The following table shows the storage content and examples for each item of the error history.
Item
Error code
Order of generation
First two digits of the year/Last two digits of the
year
Month/Day
Hour/Minute
Second
CH1 Digital output value
CH2 Digital output value
CH3 Digital output value
CH4 Digital output value
*1 This example shows the values when a second error occurred at 13:30:50, September 1st, 2012.
*2 The clock information of the error that occurred is based on the clock information acquired from the CPU module of the master station.
When an error has occurred before the clock information is acquired from the CPU module, the error time is not recorded.
b13
b12
b11
b10
b9
Storage content
The code of an error that has occurred is stored.
The order of error occurrence is stored.
(A value between 0H and FFFFH is stored.)
The value is stored in BCD code.
CH1 Digital output value when an error has
occurred is stored.
CH2 Digital output value when an error has
occurred is stored.
CH3 Digital output value when an error has
occurred is stored.
CH4 Digital output value when an error has
occurred is stored.
Address
1 to 15
0A00H to 0AEF
b8
b7
b6
b5
b4
Last two digits of the year
Day
Minute
Fixed to 00H
Storage example
0001H
2012H
0901H
1330H
5000H
Appendix 3 Details of Remote Buffer Memory Areas
b3
b2
b1
b0