Battery System - Alpha ESS STORION-T50 Installation Manual

Energy storage system
Hide thumbs Also See for STORION-T50:
Table of Contents

Advertisement

PRODUCT DESCRIPTION
Item
No.
Storion-T50-INV
AC Side Data (off-grid)
Listed: 0.8~1 leading or lagging
(Load-depend)
8
AC PF
Actual: 0.1~1 leading or lagging
(Load-depend)
100%~110% long-term;
9
Overload Capability
110%~120% 1min;
120%~150% 200ms;
DC Data (Battery Side)
10
DC Voltage Range
250 ~ 520 V
One-Way Maximum Input
11
150 A
Current
Max. DC Power
12
50 kW
PV Side Data
13
PV Voltage Range
520 ~ 900 V (MPPT: 520~800 V)
PV DC Max. Current (in case
14
192 A
of completely consumption)
Max. PV Power
15
100 kW
General Data
Max Efficiency
16
95.5%
17
800 x 2160 x 800 mm
Dimensions (W x H x L)
18
520 kg
Weight
18
Altitude
3000 m
20
Ingress Protection
IP20
21
Noise
70 dB
22
Operation Temperature
-25 ℃ ~ +50 ℃ (De-rating over 45°C)
23
Cooling Concept
Forced Air
24
Humidity
0~95% (Non-Condensing)
25
Communication Interfaces
Ethernet‚ RS-485‚ CAN
10
Storion-T100-INV
300 A
100 kW
384 A
200 kW
750 kg
11
3.3.1.4 Emergency Stop Switch
The PCS stops working immediately after pushing the button.
If you want to restart the converter, please follow the process below:
A. Conduct clockwise rotation on the emergency stop switch and then loosen the locking
status.
B. Push the AC breaker into "OFF" position, then turn the AC breaker "ON" .
C. Launch the machine and operate it as required

3.3.2. Battery System

Table 4 Battery system parameters
Item
Description
Parameter
1
28 kW ~ 50 kW / 100 kW
Nominal discharge power
According to the project
2
Energy storage capacity
situation
3
Continuous discharge
1C (continuous)
current
4
Direct voltage
250 ~ 520 V
5
Communication interface
RS485, CAN2.0
3.3.2.1 M48112-S
450 mm
Figure 3-5 M48112-S appearance and dimensions
PRODUCT DESCRIPTION
Remark
Ambient temperature is
30℃, measured at DC side

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storion-t100

Table of Contents