Parameters
P0.032■
Default:
Unit:
8
Format:
Settings:
This setting is the same as P0.025, except its mapping target is set in P0.042.
P0.033 -
P0.034
P0.035
Default:
Unit:
Format:
Settings:
The formats of the high-bit parameter (PH) and the low-bit parameter (PL) are:
BA
C
D
h
Select the data block to access the parameter corresponding to register 1. The mapping value is 32 bits
and can map to two 16-bit parameters or one 32-bit parameter.
P0.035: (Mapping parameter: P0.035; Mapping content: P0.025)
When PH ≠ PL, it indicates that the content of P0.025 includes two 16-bit parameters.
1.
Example: Target: set P2.003 to 0 in the mapping parameter and set P2.005 to 100.
8-18
Mapping parameter #8
-
-
HEX
Reserved
Target setting for mapping parameter P0.025
-
-
HEX
Hexadecimal code for the parameter index
Hexadecimal code for the parameter group
N/A
High bit
Set the P parameter
to be mapped for
P0.035
parameter value set
P0.025
by P0.035 high bit
Setting: set the P0.035 high bit to 0203 (P2.003) and low bit to 0205 (P2.005).
Thus, P0.035 = 0x02030205.
P0.035
Control mode: All
Setting range: Determined by the corresponding
Data size:
Control mode: All
Setting range: Determined by the communication
Data size:
YX
Hexadecimal code for the parameter index
Z
Hexadecimal code for the parameter group
U
N/A
L
Low bit
Set the P parameter
to be mapped for
P0.025 high bit
P0.025 low bit
Map the P
Map the P
parameter value set
by P0.035 low bit
P2.003
P2.005
Address: 0040H
0041H
parameter P0.042
32-bit
Address: 0046H
0047H
address of the parameter group
32-bit
ASDA-A3