8 Connect Earth Ground
1. Secure the mounting plate to the outside escutcheon
with (2) #8-32 x 2" flat head machine screws (Fig 7A).
2. Connect green/yellow ground wire ring terminal
to top right screw (Fig. 7B Detail).
9 Outside Cylinder Installation
1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A).
2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig 8B).
NOTE: Use lever handle holes to manipulate mortise to ease thread engagement of cylinder.
3. Use the key to rotate the cylinder clockwise until it is flush with
the surface of the escutcheon and the SARGENT logo is
right-side up.
Do not attempt to tighten all the way.
4. Tighten the cylinder clamp set screw to prevent
unscrewing of the cylinder (Fig 8C).
5. Test cylinder function:
• 70/71 Function: Key retracts
latch.
• 80/81 Function: Key retracts
latch and projects and retracts
deadbolt.
• Ensure smooth operation of
latchbolt and deadbolt.
IMPORTANT: Position cylinder so that the
SARGENT logo is right-side up.
Correct
Fig. 7B Detail
Incorrect
Fig. 8A
Harmony Series IDP-H1 Mortise Lock
Outside of Door
Fig. 8B
10
A8132C • 800-810-WIRE (9473) • www.sargentlock.com
Ground Wire
Ring Terminal
(2) #8-32 x 2"
Phillips Flat Head
Machine Screw
Fig. 7A
Cylinder Set Screw
Phillips
Screwdriver
Fig. 8C