KEB COMBIVERT CONTROL G6 VARAN Programming Manual page 26

Table of Contents

Advertisement

OPeRATOR PARAMeTeRS
Id-Text
os09
Meaning
Type
Data length
Access
Coding
Note
Id-Text
os10
Meaning
Type
Data length
Access
Coding
Note
Id-Text
os12
Meaning
Type
Data length
Access
Coding
Note
26
Name
PU max invbusy retries
Number of repetitions that are sent on the internal bus from the
power module to the controller if it rejects "inverter busy" error.
Variable
8 bit
read / write
0...255
Standard value: 200
-
Name
PU tout count
Counts the timeouts on the internal bus between control and
power unit.
Variable
16 bit
read / write
0...65535
Standard value: 0
-
Name
operator command
Default of instructions according to coding (see below)
Variable
8 bit
read / write
0: no
1: Load default values in all operator parameters
2: reinitialize pu-parameter image
Standard value: 0
-
Parameter index
0x2089
Parameter index
0x208A
Parameter index
0x208C