OPeRATOR PARAMeTeRS
Id-Text
os07
Meaning
Type
Data length
Access
Coding
Note
Id-Text
os08
Meaning
Type
Data length
Access
Coding
Note
Name
node ID
This parameter specifies the inverter address for the diagnostic
interface (DIN 66019). The parameter is an image of the system
parameter Sy06.
Variable
8 bit
read / write
0...239
Standard value: 1
-
Name
operator type
Displaying the implemented control card functions.
Variable
16 bit
read
Bit 0
Initiator
Bit1
Keyboard/dis-
play
Bit 8
LT image
Bit 10
f = 0Hz
Bit 11
STO
Bit 12...13
Bus connection
Standard value: 0
-
Parameter index
0x2087
Parameter index
0x2088
0: without
1: with initiator
0: without
1: with keyboard/LCD display
0: with power unit image
1: without power unit image
0: without
1: with f=0Hz functionality
0: without safety function
1: with safety function STO
0: without (standard)
1: CANopen
2: IO-Link
3: EtherCAT
4: VARAN