KEB COMBIVERT CONTROL G6 VARAN Programming Manual page 19

Table of Contents

Advertisement

PROCeSS DATA MAPPING
Id-Text
Name
fb19
PDO-in count
Meaning
Sets the number of PD-in objects
Type
Variable
Data length
8 bit
Access
read / write
Coding
0...8
Standard value: 0
Note
Is automatically set to 0 when changing the parameters fb15...fb18.
Id-Text
Name
co14
TPDO1 mapping
Type
Array
Meaning
Sets the number of mapped objects
Data length
8 bit
Access
read / write
Coding
0...8
Standard value: 0
Note
Successively, no gaps as on the fb-mapping parameters possible.
Meaning
Describes an object mapping. The index, subindex and the
object length are specified in bits.
Data length
32 bit
Access
read / write
Coding
Standard value: 00000100h
Note
A writing of this parameter requires that the count (subindex 0) is set to 0.
Subindex 0
Subindex 1...8
Index
Index
HB
LB
B3
B2
Parameter index
0x2193
Parameter index
0x1A00
Subindex
B1
Object length
B0
19