KEB COMBIVERT CONTROL G6 VARAN Programming Manual page 15

Table of Contents

Advertisement

PROCeSS DATA MAPPING
Id-Text
fb13
Type
Meaning
Data length
Access
Coding
Note
Meaning
Data length
Access
Coding
Note
Id-Text
fb14
Meaning
Type
Data length
Access
Coding
Note
Name
PD out type
Array
Subindex 0
Number of subindices of this object
8 bit
read
8
Standard value: 8
-
Subindex 1...8
The value specifies the parameter type of the selected PD pa-
rameter.
8 bit
read / write
0: off (no parameter type defined)
1: Long (32bit)
2: Word (16bit)
3: Byte (8 bit)
Standard value: 0
-
Name
PDO out count
Sets the number of PD out objects
Variable
8 bit
read / write
0...8
Standard value: 0
Is automatically set to 0 when changing the parameters fb10...
fb13.
Parameter index
0x218D
Parameter index
0x218E