Installation
5.3

Installing the angle sensor

If the lift is equipped with radio control, associated
angle sensor must be mounted on the platform,
see Fig 15. Use sensor bracket, art. no. 53937TL
(Ordered separately).
1. Mark the position of the bracket holes on the plat-
form and drill suitable holes.
2. Mount the bracket (Art. no. 53937TL) using the
attached two pop rivets, see Fig 15.
3. Mount the angle sensor with the connection cable
pointing upvards and out on the bracket using the
attached screws, see Fig 16.
4. Mount the cable among existing cables using cable
ties. Connection is described later in section 7.
NOTE!
The cable must be installed sufficiently far from or be
protected against sharp edges, so that it cannot chafe
or otherwise sustain damage that can lead to a short
circuit or cable fire.
In general, care must be taken whenever routing
cables, in order to ensure a longer cable service life
and to reduce the risk of unnecessary operational
stoppages.
www.zepro.com
Fig 15. Mounting of bracket and angle sensor
Fig 16. Mounted angle sensor