Installation Of Connection Ramp; Armstops; Platform Stop - Zepro ZHZ 500 Installation Instruction

Hide thumbs Also See for ZHZ 500:
Table of Contents

Advertisement

Installation
5.6

Installation of connection ramp

Install the connection ramp to that it connects 40-60
mm in on the platform.
A safety distance of 75 mm is recommended when
the platform is level with the vehicle floor.
5.7

Armstops

The armstops must be adjusted after installation of the
installation kit and lift.
Adjust with the adjustment screws, so that both arm-
stops contact the lift arms at the same time.
NOTE!
On some vehicle models, the space can be so
confined that the lift has to be lowered in order for the
adjusting screws to be accessible. If so, measure the
need for adjustment first.
5.8

Platform stop

(Applies only to folding platform)
When the lift platform is folded up and closed against
the vehicle body, the platform stop must automatically
lock the various parts of the platform against each other.
www.zepro.com
Connection ramp
Fig 19. Connection ramp
Fig 20. Armstops
Fig 21. Platform stop
ZHZ 500/600-850
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zhz 600Zhz 850

Table of Contents