1.
Turn the selector switch on the motor controller to position
2 "STOP".
2.
Disconnect the electrical cables in the outlet box.
3.
Loosen the bolts [1] and remove the electric motor.
4.
Replace the flexible coupling [2].
5.
Align the couplings and lower the motor vertically on to the
bell house.
6.
Fasten the bolts [1].
7.
Turn the selector switch on the motor controller to position 1 "REMOTE CONTROL".