Function Test Of Alarm System - Kongsberg Frydenbo IRV-2 Maintenance Manual

Steering gear
Table of Contents

Advertisement

Maintenance Manual
Please follow below procedure in order to complete a function test of the alarms on the alarm
system installed.
There is a 5 sec delay in the alarm system. If any alarm is present in the alarm system, the auto
start will not work, so please check all alarms on the alarm panel before you test the next alarm.
Alarm test
Overload
Phase failure
Power failure
Power control failure
Low oil level
Hydraulic lock
Clogged filter
High oil temp
Low oil pressure
Power failure aux. steering
Overload alarm:
Push the test button on the overload relay in motor controller. The stand-by pump should start if not
already running.
Phase failure alarm:
Remove one of the fuses supplying the phase failure monitoring relay in the motor controller
cabinet, the stand-by pump should start if not already running.
Power failure:
Turn of main switch S1 in the motor controller or the circuit breaker from switch board. The stand-by
pump should start if not already running.
Power control failure alarm:
Set the S2 selector switch located on the outside of the motor controller cabinet to local control or
stop, the stand-by pump should start if not already running.
Low oil level alarm:
Disconnect the connection plug on top of the expansion tank.
The stand-by pump should start if not already running.
Hydraulic lock
alarm:
Activate manual solenoid in either direction while the motor controller is in remote control. Keep
activated for more than 5 seconds.
The stand-by pump should start if not already running.
KONGSBERG PROPRIETARY. This document and its accompanying elements contain KONGSBERG
information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited if not
otherwise explicitly agreed with KONGSBERG in writing. Any authorized reproduction, in whole or in part, must
include this legend. ©2022 KONGSBERG - All rights reserved.

Function Test of Alarm System

Note!
Test Push Button
Remove fuse F17
Turn of main switch
Turn selector switch to position 2
Disconnect sensor from PP
Keep selector switch in remote and operate the Steering Gear locally
Disconnect sensor from PP
Disconnect sensor from PP
Close handle before starting the pump
Remove fuse F41-42-43-44
P a g e
43 |
73

Advertisement

Table of Contents
loading

Table of Contents