CS1W-PDC01 Analog Input Unit
Features
Model Information
Unit classification
CS-series Special I/O Unit CS1W-PDC01
74
• Up to four DC signal inputs can be connected per Unit. Any of the follow-
ing can be selected separately for the four inputs: 4 to 20 mA, 0 to 20 mA,
–10 to 10 V, 0 to 10 V, –5 to 5 V, 1 to 5 V, 0 to 5 V, or ± 10-V user-set range.
• Scaling values are sent to the CPU Unit in four digits hexadecimal.
• Isolation between analog inputs can prevent sneak circuits from occurring
between input signals.
• Square root function.
• Four values for each process value alarm input.
• ON-delay timer for process value alarm.
• Mean value processing.
• Rate-of-change calculation.
• Two values for each rate-of-change alarm input.
• Input error detection.
• Zero/span adjustment capability during operation.
Model number
Inputs
4 max.
Input types
The following can be selected separately: 4 to 20 mA, 0 to
20 mA, –10 to 10 V, 0 to 10 V, –5 to 5 V, 1 to 5 V, 0 to 5 V,
or ±10-V user-set range