Specification Changes
New Input Range (0 to 20 mA) for the CS1W-PDC01
Before Change
–10 to 10 V, 0 to 10 V, –5 to 5 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA, optionally set
voltages
After Change
–10 to 10 V, 0 to 10 V, –5 to 5 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA, optionally set
voltages, 0 to 20 mA (new)
The settings are shown below. (There is no need to change the setting unless
the new setting is going to be used.)
• Before Change (m = D20000 + Unit number x 100)
Offset
Input
Input
No. 1
No. 2
m+34
m+48
• After Change (m = D20000 + Unit number x 100)
Offset
Input
Input
No. 1
No. 2
m+34
m+48
Setting
range
Input
Input
No. 3
No. 4
m+62
m+76
0 to 6
Setting
range
Input
Input
No. 3
No. 4
m+62
m+76
0 to 7
Section 1-7
Setting name
Input signal
0: –10 to +10 V,
1: 0 to 10 V,
2: –5 to 5 V,
3: 0 to 5 V,
4: 1 to 5 V,
5: 4 to 20 mA,
6: User-set voltages
Setting name
Input signal
0: –10 to +10 V,
1: 0 to 10 V,
2: –5 to 5 V,
3: 0 to 5 V,
4: 1 to 5 V,
5: 4 to 20 mA,
6: User-set voltages
7: 0 to 20 mA