word length 16, 18, or 20: Selects 16-, 18-, or 20-bit output words. See step
10 on page 2-33.
dither on or off: sets dither status. See step 11 on page 2-34.
no function: remote interface disabled.
5. End remote control interface programming.
When you are finished programming the remote control interface, press the
A)
button once to return to the Remote screen.
cape
6. Set Modem Initialization String.
[Skip this step if you are not using 6200 PC Remote Control software.]
Press SET MODEM INIT soft key to access Modem Initialization screen.
A)
The 6200 powers up with a default initialization string [AT&FE0S0=4].
Always begin by using this default. If you cannot get a reliable connection
with the default, then you may edit this string as necessary. Use the
Prev
buttons to move through the characters and use the knob to set a char-
acter as desired.
To verify the string, complete the 6200 PC hardware and installation steps
(refer to 6200 PC Operating Manual), then proceed:
With the modem connected to the 6200 (modem plugged into the
6200's RS-232 connector), its AA light comes on within 10 seconds and
stays on. If the AA light doesn't come on and/or the received data light
(often labeled RD or RX) flashes at regular intervals, something is
wrong with the initialization string.
In this case, reset the MODEM INIT string for the following parame-
ters: recall factory preset, echo off, and auto-answer (Refer to the mo-
dem's manual).
If the modem initialization string is set correctly, and 6200 PC and the
6200 still do not negotiate successfully, make sure the modem is set for
V.42 operation only.
7. Complete Installation.
Installation is finished; repeatedly press the
G/R screen.
button to return to the Idle
Escape
INSTALLATION
Es-
and
Next
2-37