2-4
INSTALLATION
3. Check the line voltage, fuse and power cord.
A)
DO NOT connect power to the unit yet!
Check the Voltage Selector. This is on the rear panel.
B)
The 6200 is shipped configured for either 90-130V or 200-250V, 50Hz or
60Hz operation, as indicated on the rear panel. Refer to the unit's rear panel
for your Model Number and the inside of the front cover of this manual for
your Model Number's line voltage setting. To change the operating voltage,
set the Voltage Selector to 115V (for 90-130V) or 230V (for 200-250V) as
appropriate.
Check the value of the fuse and change the fuse if the value is incorrect.
C)
Important: If the fuse is not installed, select the appropriate fuse from the
accessory kit and install it.
For safety, fuse F1 must be Slow-Blow, ½-amp for 115V, or ¼-amp
(250mA) "T" type for 230V.
TYPE 18/3 SVT COR, TYP
TYPE H05VV - F - 0.75
PLUG FOR
230 VAC
(EUROPEAN)
Check power cord.
D)
AC power passes through an IEC-standard mains connector and an RF filter
designed to meet the standards of all international safety authorities.
The power cord is terminated in a "U-ground" plug (USA standard), or
CEE7/7 plug (Continental Europe), as appropriate to your 6200's Model
Number. The green/yellow wire is connected directly to the 6200 chassis.
If you need to change the plug to meet your country's standard and you are
qualified to do so, see Figure 2-2. Otherwise, purchase a new mains cord
with the correct line plug attached.
(3 x .82 mm
2
)
CONDUCTOR
L
NEUTRAL
N
E
EARTH GND
PLUG FOR
115 VAC
(USA)
Figure 2-2: AC Line Cord Wire Standard
WIRE COLOR
NORMAL
ALT
LINE
BROWN
BLACK
BLUE
WHITE
GREEN-YELLOW
GREEN
CONDUCTOR
WIRE COLOR
L
LINE
BROWN
N
NEUTRAL
BLUE
E
EARTH GND
GREEN-YELLOW
ORBAN Model 6200