154/233
NY4150 and NY4150/10: SERCOS III Master Module
12.10

Installation requirements

Bosch Rexroth AG R911337671_Edition 18
NYCe 4000 Multi-axis motion control system Hardware Sys‐
DRV NET
PORT1
RKB001x
PORT2
NY4150
RKB001x
IndraDrive
Fig. 12-6:
Connection ring between NY4150 and IndraDrive(s)
The type numbers of the cables between the NY4150 and the IndraDrive(s)
are the following.
RKB0013, which have a length of 25, 35 or 55 cm.
RKB0011, length is specified by the customer.
The RKB0013 is in principle meant for connection of IndraDrives that are
installed next to each other. The RKB0011 is meant to span larger distances.
The RKB0011 and RKB0013 are electrically identical.
WARNING
Make sure power supplies are switched off before installation or removal
of the NY4150 module.
Do not apply power until the NY4150 module is installed.
WARNING
Comply with all ESD protective measures while working with modules
and components. Avoid electrostatic discharges.
The RJ45 connections to the SERCOS network are located on the front of
the NY4150 module. Some form of network cable strain relief is required for
this type of connection to ensure a reliable contact between the RJ45 plug
and header. You can use the NY4901/10 cable strain relief bracket installed
on the NY4112 or NY4114 MCU, or the NY4901/40 cable strain relief bracket
RKB001x
RKB001x
IndraDrive
Damage to components may occur if power
is applied during installation or removal.
Damage to components may occur due to
electrostatic discharges.