NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
9.10
TTL Digital Inputs
signal in the cable. For normal digital I/O this is recommended, but for fast
digital I/O this is mandatory.
Characteristic
Number of inputs
Function
Signal interface
Galvanic insulated
Input thresholds
Input current
Maximum input voltage
Interface type
Input frequency
Pull-up resistor for open
collector driver
Tab. 9-11:
Characteristics for TTL digital inputs
100k
1k
TTLIn
100 nF
DGND
Fig. 9-11:
Input circuit of the digital inputs TTLIn0...4
Notes
NY4125: 5-axis low power PWM Drive Module
Description
5, TTLIn0 ... TTLIn4
General purpose digital Input (for example for encoder
error signal). Other general purpose digital input
functionality,
such
as
edge
functionality, etc., is not supported.
In NYCe 4000 Software these inputs are referenced
with the following definitions:
●
Input
TTLIn0
–
referenced
NYCE_DIG5VIN0A
●
Input
TTLIn1
–
referenced
NYCE_DIG5VIN0B
●
Input
TTLIn2
–
referenced
NYCE_DIG5VIN0C
●
Input
TTLIn3
–
referenced
NYCE_DIG5VIN1A
●
Input
TTLIn4
–
referenced
NYCE_DIG5VIN1B
TTL logic
No
Input "low" voltage range: 0 ... 0.8 V
Input "high" voltage range: 2.0 ... 5.5 V
Typical 40 µA (input "low"), 1.4 mA (input "high")
–5 ... +10 V ±0.5 V
TTL
1 MHz
No
+3.3V
74LVT14
R911337671_Edition 18 Bosch Rexroth AG
95/233
detection,
counter
by
identifier
by
identifier
by
identifier
by
identifier
by
identifier