Magnetic flux
Depending on the application, the strength of the magnetic flux density on the
densities within
individual areas of the welding torch can be controlled by regulating how deeply
the cleaning coil
the welding torch is immersed in the cleaning coil.
for Robacta TC
2000, Robacta
NOTE!
TC 2000 US
When using the cleaning device, refer to the program sequence for details of the
welding torch immersion depth.
(1)
(2)
(3)
20
(1)
Cleaning coil
Diagram showing available magnetic flux density
Immersion depth of torch neck into cleaning coil
(2)
0 %
100 %
(3)
15 mm
10 mm
0.59 in.
0.39 in.
50 mm
1.97 in.