Connecting Entrance Stations

Most systems involve the use of not only a master station but
entrance stations as well. The D4000 system entrance stations
must:
• be "slaved" to the master to station which they remotely
control, and,
• have a unique network address.
To connect an entrance station to the system:
Determine the network id for the entry station
Step 1:
If already installed, remove the entry station from the
Step 2:
wall and unplug the network cable
Set the Network ID dipswitch to the Network ID of the
Step 3:
master station to which this device should be slaved
Hold down the upper left button on the device and
Step 4:
plug in the network connector
Unplug the network connector
Step 5:
Set the Network ID dipswitch to the appropriate
Step 6:
network id of the entry station
Plug the network cable back into the device and install
Step 7:
the unit into the wall.
Leviton Dimensions 4000 Series Architectural Lighting Controller
• After approximately 10 seconds, the green
LED's will blink. Once this occurs, the id
has been successfully programmed and
you can move on to the next step.
Configuration Guide
Page 42