• Inactive Scene
indicates the event/scene which should be recalled when
the input goes in-active. If using is the OCC input, an
inactive input is indicated by the input being 'open' or
common. If the input used is the LOCK input, an inactive
input is indicated by the input being 'open' or connected
to common +V. Event settings for the inactive scene are
the same as for the active scene.
• Lock User Interface
indicates whether or not the user interface should be
'locked' when the input goes active, and 'unlocked' when
the input goes inactive. When the user interface is
locked, no operation or configuration changes may be
made. The valid settings for this property are:
Blink Warn Override Time
This setting sets the time between when a blink warn is
overridden and the time when the next blink warn for the same
event is issued. For example, let's assume that a device currently
has scene 1 active, and at 5:30pm the off scene will be triggered
with a blink warn. The blink warn override time is set to 1 hour.
The sequence of events would be as follows:
• 5:00pm - Scene 1 Active
• 5:30pm - Off Scene with Blink activated by scheduler
Page 39
• None - nothing happens
• S01....S16 - Scenes 1-16
• MAX - Max Scene
• OFF -Off Scene
MISC: UNLCK/UNOCC
EVENT:
MISC SETTINGS
LOCK: ENABLE
• Enabled - The user interface should be
locked when the input is active.
• Disabled - The user interface should not
be locked when this input is active.
S01