Devices with Channel Control only (D4200)
Setting up units with control and dimmers require a few basic
steps which when followed will ensure success of your lighting
control system:
Confirm all connections have been completed.
Step 1:
Network connections are required
Connection to adequate power supply is required
Lock/Occ input is an optional connection
Confirm network is terminated correctly, reference
Step 2:
installation guide for additional information.
Complete all "System Layout Charts" on page 68 to
Step 3:
confirm a clear understanding of all system and
configuration requirements.
Review "Navigating the Menus" on page 49
Step 4:
Power up unit
Step 5:
Perform "Power Up Initialization" on page 16 or review
Step 6:
"Setting the Network ID" on page 20
Perform setup of other network devices, dimmers, etc.
Step 7:
Confirm this device is patched to the correct channels.
Step 8:
Reference "To Assign Zones, consecutively, from a
Starting Channel Number:" on page 25.
Push the MAX button
Step 9:
Slave any remote/entrance stations to this device.
Step 10:
(p.42)
Configure the clock - Set the date & time. See
Step 11:
"Configure the Clock" on page 52.
If scheduling events around sunrise or sunset, setup
Step 12:
the astronomical time clock on page 53.
Record your scenes, see "Recording a Scene" on
Step 13:
page 53.
Leviton Dimensions 4000 Series Architectural Lighting Controller
• CONFIRM that all loads controlled by this
device go to full. If they DO,
CONGRATULATIONS! You have made it a
long ways towards a successful
installation. If they DO NOT go to full,
please reference the troubleshooting
section on page 70 for additional
troubleshooting steps.
Configuration Guide
Page 14