STATus:OPERation:NTRansition <NR1>
Sets the value of the NTR (Negative-Transition) registers. These registers serve
as a polarity filter between the Operation Condition and Operation Event regis-
ters. When a bit in the NTR register is set to 1, then a 1-to-0 transition of the cor-
responding bit in the Operation Condition register causes that bit in the
Operation Event register to be set. STATus:PRESet sets all bits in the PTR
registers and clears all bits in the NTR registers.
•
•
•
Group
STATus
Syntax
STATus:OPERation:NTRansition <NR1>
Arguments
<NR1>
A decimal value corresponding to the binary weighted sum of the register's bits.
Setting range: 0 to 65535.
Default Value
0
Example
Enable bit 3 and 4 in the NTR register: STATus:OPERation:NTRansition 24
Query Syntax
STATus:OPERation:NTRansition?
If the same bits in both NTR and PTR registers are set to 1, then any transi-
tion of that bit at the Operation Condition register sets the corresponding bit
in the Operation Event register.
If the same bits in both NTR and PTR registers are set to 0, then no transi-
tion of that bit at the Operation Condition register can set the corresponding
bit in the Operation Event register.
The value returned is the binary-weighted sum of all enabled bits in the
register.
Copyright © Itech Electronic Co., Ltd.
STATus Subsystem
84
Need help?