5800TM Module automatic ** These module addresses apply to VISTA-20P only. †† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
Entries apply to the ADEMCO VISTA-15P/VISTA-15PSIA and ADEMCO VISTA-20P/VISTA-20PSIA controls, except entries shown in dashed boxes, which apply only to the VISTA-20P/VISTA-20PSIA (partition entries) and are not applicable to the VISTA-15P/VISTA-15PSIA. In addition, where noted, certain fields have special settings when used with the VISTA-20PSIA/VISTA-15PSIA (indicated by...
+[#] + [0] + 2 = test report sent every 28 day 2 = 45 seconds 8 = 4 min #+14 = 12 min Each mode sets schedule 32 (VISTA-20P) or schedule 08 (VISTA-15P) 3 = 60 seconds 9 = 5 min #+15 = 15 min to the stated repeat option;...
∗ ∗ ∗ ∗ 88 ∗ ∗ ∗ ∗ 96 , ∗ ∗ ∗ ∗ 97 Program Mode Lockout Options Initialize/Reset Defaults This is a command, not a data field. See page 2. 0 = standard *98 installer code lockout (reentry only by [∗] + [#] within ∗...
Page 6
Touch Screen (AUI) device 1: Must set AUI device address to 1 Touch Screen (AUI) device 2: Must set AUI device address to 2 VISTA-20P: Enter each touch screen keypad’s home partition 0 = disable; 1 = partition 1; 2 = partition 2; 3 = partition 3 (common) VISTA-15P: 0 = disable;...
Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182- *185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below.
90-91 = Configurable Press [∗] to return to the ENTER ZN NUM prompt. PARTITION 1, 2, or 3-common (VISTA-20P) REPORT CODE ∗ ∗ ∗ ∗ 58 Expert Zone Programming Mode 1-9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F For Contact ID®, enter any non-zero entry as the first digit to enable...
00 = For the Function key selected, the function will be as follows (default): NOTE: Macros 11-12 apply to VISTA-20P only If A selected = Zone 95 (emergency key, same as [1] [∗] pair) Press [∗] to continue; returns to key number prompt with the next function key letter If B selected = Zone 99 (emergency key, same as [∗] [#] pair)
The *79 Device Mapping Worksheet is on page 14. Enter the device output number (programmed in *79 Menu Mode) you want associated with this output. 01-16 = VISTA-20P output no.; 01-08 = VISTA-15P output no.; 17-18 = on- ENTER OUTPUT NO. board triggers 01-18 = VISTA-20P relays/X-10;...
“DISARMED Ready to Arm” message. programmed to display using Scheduling Mode. VISTA-20P: Use the following word numbers in step 2: 3. Refer to the Character (ASCII) Chart on the next page. 11 = partition 1; 12 = partition 2; 13 = common lobby Press [#], followed by the two-digit entry for the first letter you would like to display (e.g., # 6 5 for “A”).
SCHEDULES WORKSHEET (installer code + [#] + [6] [4]; master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and events 00-07 for both controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules ) Event Device No.
Page 13
*56 ZONE PROGRAMMING WORKSHEET (VISTA-15P supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardwire Rsp. Time Location Type [09] [EOL] [01] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL]...
Page 14
OUTPUT RELAYS/POWERLINE CARRIER (X-10) DEVICES WORKSHEET FOR ∗ ∗ ∗ ∗ 79, ∗ ∗ ∗ ∗ 80 and ∗ ∗ ∗ ∗ 81. Applicable only if Relays and/or Powerline Carrier Devices are to be used. ∗ ∗ ∗ ∗ 79 RELAY/POWERLINE CARRIER (X-10) DEVICE MAPPING (Must program before using *80) OUTPUT TYPE OUTPUT TYPE (09-16 apply to VISTA-20P only) Relay Relay Output...
Page 15
✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. ✱...