Honeywell ADEMCO VISTA-20P Programming Manual

Honeywell ADEMCO VISTA-20P Programming Manual

Ademco vista series security systems
Hide thumbs Also See for ADEMCO VISTA-20P:

Advertisement

ADEMCO VISTA SERIES
VISTA-20P / VISTA-20PSIA
VISTA-15P / VISTA-15PSIA
Security Systems
Programming Guide
K5305-1PRV5 10/04 Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell ADEMCO VISTA-20P

  • Page 1 ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide K5305-1PRV5 10/04 Rev. A...
  • Page 2: Programming Mode Commands

    TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control): A. POWER UP, then press [ ✱ ] and [#] at the same time, within 50 seconds of powering up (this method must be used if ✱ 98 was used to exit program mode).
  • Page 3: Basic Codes

    PROGRAMMING FORM Entries apply to the ADEMCO VISTA-15P/VISTA-15PSIA and ADEMCO VISTA-20P/VISTA-20PSIA controls, except entries shown in dashed boxes, which apply only to the VISTA-20P/VISTA-20PSIA (partition entries) and are not applicable to the VISTA-15P/VISTA-15PSIA. In addition, where noted, certain fields have special settings when used with the VISTA-20PSIA/VISTA-15PSIA (indicated by...
  • Page 4: System Status Report Codes

    ∗ ∗ ∗ ∗ 66 ∗ ∗ ∗ ∗ 49 Arm Away/Stay Rpt Code Split/Dual Reporting 0 = Standard/backup reporting only (all to primary) [0,0,0,0,0,0] Primary Phone No. 2nd Phone No. Away Stay Away Stay Away Stay 1 = Alarms, Restore, Cancel Others Part.
  • Page 5: Pager Options

    ∗ ∗ ∗ ∗ 88 ∗ ∗ ∗ ∗ 96 , ∗ ∗ ∗ ∗ 97 Program Mode Lockout Options Initialize/Reset Defaults This is a command, not a data field. See page 2. 0 = standard *98 installer code lockout (reentry only by [∗] + [#] within ∗...
  • Page 6 MISCELLANEOUS SYSTEM FIELDS (*174-*181) KEYPAD OPTIONS *190-*196 ∗ ∗ ∗ ∗ 174 NOTES: 1. Options for keypad address 16 are set by the factory and cannot Clean Me Reporting Options be changed.) 2. Each keypad must be assigned a unique address. Keypads (for ESL smoke detectors) programmed with the same address will give unpredictable results.
  • Page 7: Configurable Zone Types Worksheets

    Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182- *185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below.
  • Page 8: 56 Zone Programming Menu Mode

    *56 Zone Programming Menu Mode (press *56 while in Program mode) The Zone Programming Worksheet is on page 13. For each of the following prompts, make the desired entry, followed by the [∗] key to accept the entry. Refer to the Installation and Setup Guide for detailed explanations for each prompt. XMIT TO confirm SET TO CONFIRM? Appears if you answered “Yes”...
  • Page 9: 57 Function Key Programming

    Wireless Key Programming Templates (press the [D] key from *58 Menu mode Summary Screen) This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user number (see System Operation section, Assigning Attributes Command in the Installation Instructions). TEMPLATE ? ENTER START ZONE The system displays the lowest zone number of the highest available...
  • Page 10: 82 Alpha Descriptor Programming

    ∗ ∗ ∗ ∗ 79 Menu Mode ∗ ∗ ∗ ∗ 80 Menu Mode (continued) (press ∗ ∗ ∗ ∗ 79 while in Programming mode) ENTER OUTPUT NO. The *79 Device Mapping Worksheet is on page 14. Enter the device output number (programmed in *79 Menu Mode) you want associated with this output.
  • Page 11: Alpha Vocabulary List (For Entering Zone Descriptors)

    *82 Alpha Descriptor Programming (continued) ADDING CUSTOM WORDS (up to 10 words) 4. Repeat Step 3 to create the desired word(s). Each word can be a For custom words, the keys have the following functions: maximum of 10 characters (except custom message/partition descriptor [4] moves cursor one space to the left.
  • Page 12: Schedules Worksheet

    Setting Schedules (Installer Code + [#] + [6] [4]) GROUP NUMBER ( for event 2 user access) ENTER SCHED NO. 1-8; [∗] to continue. VISTA-20P: 01-16 = end-user schedules; 17-32 = installer-only schedules PARTITION ( for events 3-7,10,12) VISTA-15P: 01-04 = end-user schedules; 05-08- = installer-only schedules 0 = all partitions;...
  • Page 13 *56 ZONE PROGRAMMING WORKSHEET (VISTA-15P supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardwire Rsp. Time Location Type [09] [EOL] [01] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL]...
  • Page 14 *57 FUNCTION KEY WORKSHEET Comments Option Function P1 P2 P1 P2 P1 P2 P1 P2 Paging Time Display Arm AWAY Arm STAY Arm NIGHT-STAY Step Arming Device Activation Device: Comm. Test Macro Key 1 Assign each macro key to only a single partition. †...
  • Page 15 ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. ✱...
  • Page 16 165 Eileen Way, Syosset, NY 11791 Copyright © 2003 Honeywell International Inc. www.honeywell.com/security ÊK5305-1PRV5VŠ K5305-1PRV5 10/04 Rev. A...

Table of Contents