Exiting the User Edit Mode

Press either [T] or [#], or don't press any key for 10 seconds.
Bank Safe and Vault
The Bank Safe or Vaul t should be l imit ed t o i t s own par t it ion wher e only a M ast er or M anager code woul d
be all owed t o oper at e (see Sect i on 2 of t hi s M anual - Par t it i oning). I f r egular user s ar e enabled t her e i s a
way t o di sabl e t heir access (see bel ow):
1. Ent er Scheduling M ode by ent er ing I nst al ler Code + [#] + [80].
2. Sel ect Time Windows.
3. Cr eat e Time Window 01 as -6:00am-10:00am.
4. Cr eat e Time Window 02 as 9:30pm-10:00pm, ent er 00* t o exi t Time Windows.
5. Do not Quit M enu M ode, go t o O/C Schedules.
6. Ent er Vault Par t it ion #.
7. Assign Window 01 as t he OP window and Window 02 as t he Cl Window for M onday t hr u Sat ur day. Exit
Pr ogr am mode.
Vault Partition
1. Pr ogr am 2 ∗ 05 = 00, Aut o-Ar m Delay (par t i t i on-specific) Ar m at 10pm.
2. Pr ogr am 2 ∗ 06 = 00, Aut o-Ar m War ning Per i od (par t it i on-specific) N o War ni ng Per i od.
3. Pr ogr am 2 ∗ 07 = 00, Aut o-Disar m Del ay (par t i t i on-specific) Di sar m at 6am.
4. Pr ogr am 2 ∗ 08 = 1, For ce Ar m (par t it ion-specific) Enabl e.
5. Pr ogr am 2 ∗ 10 = 1, Al low Disar ming Only Dur ing Ar m/Disar m Windows (par t it ion-specific).
6. Pr ogr am 2 ∗ 11 = 0, Al low Disar m Out side Window if Alar m Occur s.
Panel wil l ar m at 10pm M onday t hr u Sat ur day wi t h no war ning and Only M ast er /M anager can di sar m
bet ween 10pm and 6am.
To al so Disabl e t he M ast er /M anager fr om Disar ming bet ween 10pm and 6am All M ast er /M anager codes will
only wor k bet ween 6am and 10pm M onday t hr u Sat ur day. They wi ll not wor k on Sunday or H ol idays.
1. Ent er pr ogr am mode I nst all er s code + #80
2. Ent er 'Time Windows' and Cr eat e window 03 for 6:00am-10:00pm, ent er 00 + ∗ t o exi t Time Windows
3. Do not Quit M enu M ode, go t o Access Sched.
4. Cr eat e Access Sched 01 by assigning Window 03 t o A1 M onday t hr u Sat ur day. Exit Pr ogr am mode
5. Assign all M ast er and M anager Codes t o Access Schedul e 01 when user codes ar e assigned.
Open and Cl osed window can be r emoved fr om schedule for Sat ur day t o pr event r egular user s (if t hey ar e
enabled for t hi s par t icular par t it ion) fr om being abl e t o disar m on Sat ur day, and window can be r emoved
fr om L imit Access Gr oup 1 for Sat ur day t o pr event M ast er /M anager Access on Sat ur day.
1 Ent er pr ogr am mode I nst all er s code + #80.
2. Go t o O/C Schedul es.
3. Ent er Vault Par t it ion, go t o Sat ur day and ent er 00 for OP and CL window.
4. Go t o Access Schedul es.
5. Ent er Schedul e 01, go t o Sat ur day and ent er 00 for Window A1. Exi t pr ogr am mode.