2. Install new valve cover gaskets onto the valve
covers. See Figure 11-39.
Figure 11-39. Installing Valve Cover Gaskets.
3. Install the valve covers with gaskets in their
original locations.
4. Install the lower two mounting screws in each
cover, and finger tighten only. Upper screws will
be installed later. See Figure 11-40.
Figure 11-40. Installing Valve Covers.
Reinstall Coolant Drain Plugs
1. Reinstall the brass coolant drain plugs in the
sides of the crankcase, (and also the cylinder
head plugs, if removed during head servicing).
Apply pipe sealant with Teflon
or equivalent) to the threads and reinstall the
plugs. Torque the plugs to 13.5 N·m (120 in. lb.).
See Figure 11-41.
Figure 11-41. Installing Coolant Drain Plugs.
Install Water Pump, Drive Belt, and
Transfer Tube Assembly
1. Remove the seal protector and/or protective tape
®
(Loctite
®
59241
Figure 11-42. Installing Camshaft Key into Keyway.
(if used) from over the keyway and make sure the
end of the camshaft is clean and free of any nicks
or damage. Install and fully seat the key, squarely
into the keyway. Be careful not to contact the
camshaft seal. Test fit the cam pulley onto the
shaft and key; it must slide on without force or
restriction. Remove the pulley. See Figures 11-42
and 11-43.
NOTE: A mark or dot of paint applied to the
top, of the pulley, indicating the keyway
location, will make installation easier.