Figure 8-24. Retaining Ring Detail.
11. Remove the retainer from the armature shaft.
Save the stop collar.
NOTE:
Do not reuse the old retainer.
Figure 8-26. Delco-Remy Starter.
Collar
Ring
Stop
Drive
Armature
Washer
Tube
Electrical System and Components
Figure 8-25. Removing Retaining Ring.
12. Remove the drive pinion assembly from the
armature.
13. Clean the parts as required.
NOTE: Do not soak the armature or use solvent
when cleaning. Wipe clean using a soft cloth,
or use compressed air.
Screw
Plunger
Spring
Lever
Plate
Plug
Solenoid
Frame & Field
Brush Holder
Nut
CE Frame
Screw